SCHURTER_Logo_white.eps
Menu openMenu Close
SearchSearchSearchSearch
What are you looking for?

SCHURTER Electronic components Catalog


DC12  Screw-on mounting from front side
Screw-on mounting
from front side
DC12  Snap-in version from front side
Snap-in version
from front side
DC12  Screw-on mounting from front side, protection class II
Screw-on mounting
from front side, protection class II
DC12  Screw-on mounting from rear side
Screw-on mounting
from rear side
DC12  Screw-on mounting from front side
DC12  Snap-in version from front side
DC12  Screw-on mounting from front side, protection class II
DC12  Screw-on mounting from rear side

Series

DC12

IEC Appliance Inlet C14 with Filter, Line Switch 1- or 2-pole, Front or Rear Side Mounting

Free Sample Request

81 Variants


Connectors (Inlets/Outlets)

C14
Connector Logo
70° C
C18
Connector Logo
70° C

Description

  • Panel mount: Screw-on version from front or rear side, snap-in version front side
  • 3 Functions: Appliance Inlet protection class I or II, Line Switch 1  or 2 pole, Line filter in standard and medical version
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • Compact power entry module
  • Available in white or black
  • Switch for high inrush current
  • V-Lock cord retaining

Characteristics

  • Compact design with optimal shielding
    Rear side mounting for efficient costsaving assembly
  • All single elements are already wired
  • Line switch non-illuminated or illuminated
  • Universal line filter for standard applications
  • Ideal for application with high transient loads
  • For applications according IEC/UL 62368-1 we recommend variants with bleed resistor
    Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP)

Other versions on request

  • Solder terminals
  • Other rocker marking
  • Capacitance CX1

Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path.
In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information about the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.
Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.
The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects. Details about IP protection degree can be looked up in the general product information
IP-Protection

front side IP40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information
Protection against electric shock

Suitable for appliances with protection class I or II acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.
Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

Quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Panel Thickness S


See details in drawing
Snapper

Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm

Material

Thermoplastic, black / white, UL 94V-0

Appliance inlet/-outlet

Appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42
Details on connectors and their names can be found in the general product information
Appliance Couplers Mating Connectors Term explanation Special Connector Designs

C14 / C18 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II

Line Switch

Line Switch


Also includes circuit breaker switch and switch for Bowden cables.

Details about the switches can also be found in the general product information.
Line Switch

Rocker switch 1-/2-pole, non-illuminated or illuminated, acc. to IEC 61058-1
Technical Details

Line Filter

Filter Type


Filter classification according leakage current for easy reading:
Standard: < 0.5 mA
Medizinal: < 0.1 mA
Leakage Current

Standard and Medical Version, IEC 60939, UL 60939-3, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 1'900'000 h acc. to MIL-HB-217 F

020060160000001535

Short Table of Variants DC12 Open complete table DC12

Rated current Filter-Type Panel mounting Order Number
Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application.
Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
[A]              
             



 
1 Standard version Snap-in DC12.1102.103 ...
2 Standard version Snap-in DC12.2102.103 ...
4 Standard version Snap-in DC12.3102.103 ...
6 Standard version Snap-in DC12.4102.103 ...
10 Standard version Snap-in DC12.5102.103 ...
1 Standard version Snap-in DC12.1102.101 ...
2 Standard version Snap-in DC12.2102.101 ...
4 Standard version Snap-in DC12.3102.101 ...
6 Standard version Snap-in DC12.4102.101 ...
10 Standard version Snap-in DC12.5102.101 ...
1 Standard version Screw DC12.1102.203 ...
2 Standard version Screw DC12.2102.203 ...
4 Standard version Screw DC12.3102.203 ...
6 Standard version Screw DC12.4102.203 ...
10 Standard version Screw DC12.5102.203 ...
1 Standard version Screw DC12.1102.201 ...
2 Standard version Screw DC12.2102.201 ...
4 Standard version Screw DC12.3102.201 ...
6 Standard version Screw DC12.4102.201 ...
10 Standard version Screw DC12.5102.201 ...
1 Standard version Screw DC12.1102.003 ...
2 Standard version Screw DC12.2102.003 ...
4 Standard version Screw DC12.3102.003 ...
6 Standard version Screw DC12.4102.003 ...
10 Standard version Screw DC12.5102.003 ...
1 Standard version Screw DC12.1102.001 ...
2 Standard version Screw DC12.2102.001 ...
4 Standard version Screw DC12.3102.001 ...
6 Standard version Screw DC12.4102.001 ...
10 Standard version Screw DC12.5102.001 ...
1 Medical Version (M5) Snap-in DC12.1202.103 ...
2 Medical Version (M5) Snap-in DC12.2202.103 ...
4 Medical Version (M5) Snap-in DC12.3202.103 ...
6 Medical Version (M5) Snap-in DC12.4202.103 ...
10 Medical Version (M5) Snap-in DC12.5202.103 ...
6 Medical Version (M5) Snap-in DC12.4232.101 ...
1 Medical Version (M5) Snap-in DC12.1202.101 ...
1 Medical Version (M5) Snap-in DC12.1202.121 ...
1 Medical Version (M5) Snap-in DC12.1202.131 ...
2 Medical Version (M5) Snap-in DC12.2202.101 ...
2 Medical Version (M5) Snap-in DC12.2202.121 ...
2 Medical Version (M5) Snap-in DC12.2202.131 ...
4 Medical Version (M5) Snap-in DC12.3202.101 ...
4 Medical Version (M5) Snap-in DC12.3202.121 ...
4 Medical Version (M5) Snap-in DC12.3202.131 ...
6 Medical Version (M5) Snap-in DC12.4202.101 ...
6 Medical Version (M5) Snap-in DC12.4202.121 ...
6 Medical Version (M5) Snap-in DC12.4202.131 ...
10 Medical Version (M5) Snap-in DC12.5202.101 ...
10 Medical Version (M5) Snap-in DC12.5202.121 ...
10 Medical Version (M5) Snap-in DC12.5202.131 ...
1 Medical Version (M5) Screw DC12.1202.201 ...
2 Medical Version (M5) Screw DC12.2202.201 ...
4 Medical Version (M5) Screw DC12.3202.201 ...
6 Medical Version (M5) Screw DC12.4202.201 ...
10 Medical Version (M5) Screw DC12.5202.201 ...
1 Medical Version (M5) Screw DC12.1202.003 ...
2 Medical Version (M5) Screw DC12.2202.003 ...
4 Medical Version (M5) Screw DC12.3202.003 ...
6 Medical Version (M5) Screw DC12.4202.003 ...
10 Medical Version (M5) Screw DC12.5202.003 ...
1 Medical Version (M5) Screw DC12.1202.001 ...
1 Medical Version (M5) Screw DC12.1202.021 ...
1 Medical Version (M5) Screw DC12.1202.031 ...
2 Medical Version (M5) Screw DC12.2202.001 ...
2 Medical Version (M5) Screw DC12.2202.021 ...
2 Medical Version (M5) Screw DC12.2202.031 ...
4 Medical Version (M5) Screw DC12.3202.001 ...
4 Medical Version (M5) Screw DC12.3202.021 ...
4 Medical Version (M5) Screw DC12.3202.031 ...
6 Medical Version (M5) Screw DC12.4202.001 ...
6 Medical Version (M5) Screw DC12.4202.021 ...
6 Medical Version (M5) Screw DC12.4202.031 ...
10 Medical Version (M5) Screw DC12.5202.001 ...
10 Medical Version (M5) Screw DC12.5202.021 ...
10 Medical Version (M5) Screw DC12.5202.031 ...
1 Medical Version (M80) Screw DC12.1602.201 ...
2 Medical Version (M80) Screw DC12.2602.201 ...
4 Medical Version (M80) Screw DC12.3602.201 ...
6 Medical Version (M80) Screw DC12.4602.201 ...
10 Medical Version (M80) Screw DC12.5602.201 ...

Packaging unit 10 Pcs 

020060160000001535

27.02.2025
en prod By changing the catalog version (Desktop <> Mobile), the system is resetting the chosen filters
ScrollToTop
ShareShare
ShareShare on Linkedin
Copy link
Send via e-mail
CloseYou will be transferred to the selected country page address. Therefore you will leave the SCHURTER main page.
If you would you like to visit your selected country page, please click on the button below:
If you would like to stay on the SCHURTER global website, please click on the button below:www.schurter.com
Note: Your country preferences for the SCHURTER Global Website are now saved.